Electronic Data Center. Delivering Direct Online Access to Scientific, Engineering, and Medical Reference Material and Information

ICHMT DIGITAL LIBRARY ONLINE

ISSN
961-91393-0-5

Print version

Year 2001

Volume 1 - CHT'01 - Advances in Computational Heat Transfer II
Proceedings of a Second Symposium - Palm Cove, Queensland, Australia, May 20 - 25, 2001

ARTICLE:

C. S. Utkarsh
Atomic Energy Regulatory Board, Niyamak Bhavan, Anushakti Nagar, Mumbai-400094, India

J. B. Doshi
Department of Mechanical Engineering, Indian Institute of Technology, Bombay, Powai, Mumbai-400076, India.


ABSTRACT

The transient analysis of U-tube steam generator commonly used in nuclear power plants is carried out using an Extended Implicit Continuous Eulerian (EICE) solution method. A one dimensional finite difference formulation is developed to solve mass, momentum and energy conservation equations in the primary and the secondary legs of the steam generator. An empirical two-phase slip flow model is also included in the formulation. The numerical results obtained are compared with the experimental data reported in the literature and reasonably good agreement is observed.

 download article

333-340 pages